Shell and tube heat exchangers are a type of heat exchanger widely used in various industries to transfer heat between two fluids. They consist of a shell, which is a cylindrical vessel, and a bundle of tubes inside the shell. The two fluids flow through the shell and the tubes, respectively, allowing heat to be exchanged between them. The shell and tube heat exchanger operates on the principle of heat transfer through conduction. One fluid, known as the process fluid, flows through the tubes, while the other fluid, known as the service fluid, flows through the shell. The process fluid is heated or cooled as it passes through the tubes, while the service fluid absorbs or releases heat as it flows through the shell. The design of shell and tube heat exchangers allows for efficient heat transfer due to the large surface area provided by the numerous tubes. The tubes are typically made of materials with good thermal conductivity, such as copper or stainless steel, to enhance heat transfer. The shell is designed to withstand the pressure of the fluids and is often made of steel. Shell and tube heat exchangers are versatile and can be used in various applications, including power plants, chemical processing, refrigeration systems, and HVAC systems. They are particularly suitable for high-pressure and high-temperature applications due to their robust construction. In conclusion, shell and tube heat exchangers are essential devices for transferring heat between two fluids. Their design allows for efficient heat transfer, making them widely used in various industries.

Achetez et vendez des équipements Shell And Tube Heat Exchangers d'occasion chez FEC Assets. Nous offrons une large sélection d'équipements Shell And Tube Heat Exchangers de seconde main, remis à neuf et d'occasion pour les industries pharmaceutiques, chimiques, alimentaires et d'emballage. Consultez notre inventaire actuel d'équipements Shell And Tube Heat Exchangers d'occasion à vendre, ou contactez-nous pour vendre vos équipements Shell And Tube Heat Exchangers excédentaires par le biais de notre service professionnel de récupération des investissements.


Shell And Tube Heat Exchangers Fabricants

ITT logo

ITT

Notre stock d'ITT comprend 18 articles référencés, principalement des réservoirs et des cuves ; 12 d

Standard Refrigeration

Un article d'occasion de la gamme Standard Refrigeration a été mis en vente sur FEC Assets ; il est

Thermotran

Notre stock Thermotran comprend 1 article référencé, classé dans la catégorie des échangeurs de chal

Yula logo

Yula

Notre stock de produits Yula comprend 1 article référencé, classé dans la catégorie des échangeurs d

Filtre

Articles trouvés : 8
8 résultats
 4949-7

450 Sq Ft Ambassador Heat Transfer Heat Exchanger, 304L S/S, 165/165#

Échangeur de chaleur Ambassador Heat Transfer non utilisé, d'une superficie de 450 pieds carrés, avec des tubes, des plaques tubulaires et des couvercles en acier inoxydable 304L (114).Tubes de 75" de diamètre x 240" de longueur, conçus pour une pression nominale de 165 psi à 400 °F ; enveloppe en acier au carbone conçue pour une pression nominale de 165 psi à 400 °F ; n° de série 06-1071-73 ; n° ...

4949-7
Henry Technologies LTD. 3075-16

1,915 Sq Ft Henry Tech Heat Exchanger, 304 S/S, 150/250#

Échangeur de chaleur à calandre et tubes d'occasion de la société Henry Technologies LTD, d'une superficie de 1 915 pieds carrés, avec des tubes, des plaques tubulaires et des couvercles en acier inoxydable 304, comprenant (488) tubes de 0,75" de diamètre x 20' de longueur, conçus pour une pression nominale de 150 psi à 150 °F, une enveloppe en acier au carbone conçue pour une pression nominale de...

Henry Technologies LTD. - 3075-16
Henry Technologies LTD. 3075-15

1,915 Sq Ft Henry Tech Heat Exchanger, 304 S/S, 150/250#

Échangeur de chaleur à calandre et tubes d'occasion de la société Henry Technologies LTD, d'une superficie de 1 915 pieds carrés, avec des tubes, des plaques tubulaires et des chapeaux en acier inoxydable 304, comprenant (488) tubes de 0,75" de diamètre x 20' de longueur, conçus pour une pression nominale de 150 psi à 150 °F, une enveloppe en acier au carbone conçue pour une pression nominale de 2...

Henry Technologies LTD. - 3075-15
Henry Technologies LTD. 3075-17

1,915 Sq Ft Henry Tech Heat Exchanger, 304 S/S, 150/250#

Échangeur de chaleur à calandre et tubes d'occasion de la société Henry Technologies LTD, d'une superficie de 1 915 pieds carrés, avec des tubes, des plaques tubulaires et des couvercles en acier inoxydable 304, comprenant (488) tubes de 0,75" de diamètre x 20' de longueur, conçus pour 150 psi à 150 °F, une enveloppe en acier au carbone conçue pour 250 psi à 200 °F, des raccords d’entrée/sortie de...

Henry Technologies LTD. - 3075-17
Henry Technologies LTD. 3075-14

1,915 Sq Ft Henry Tech Heat Exchanger, 304 S/S, 150/250#

Échangeur de chaleur à calandre et tubes d'occasion de Henry Technologies LTD, d'une superficie de 1 915 pieds carrés, avec des tubes, des plaques tubulaires et des chapeaux en acier inoxydable 304, comprenant (488) tubes de 0,75" de diamètre x 20' de longueur, conçus pour 150 psi à 150 °F, une enveloppe en acier au carbone conçue pour 250 psi à 200 °F, des raccords d'entrée/sortie de *" pour les ...

Henry Technologies LTD. - 3075-14
Standard Refrigeration AHX1006A2

Standard Refrigeration Ketema LP (ACME) Horizontal Chiller Condensor, Size AHX1006A2

Refroidisseur standard non utilisé - Condenseur de refroidisseur horizontal à double circuit Ketema LP (ACME), enveloppe en acier au carbone (CS), tubes en cuivre, têtes en fonte, plaques tubulaires en acier. Modèle standard AHX1006A2. Pression de service maximale de 350 psi à 250 °F, température minimale de conception du métal de 20 °F à 350 psi. National Board 560112, numéro de série 560112.

Standard Refrigeration - AHX1006A2
ITT 5-060-13-048-006

118 Sq Ft ITT Heat Exchanger, 304 S/S, 152/152#

Échangeur de chaleur à calandre et tubes ITT d'occasion, d'une surface de 11 m², avec des tubes en acier inoxydable 304 d'un diamètre de 38,5 cm et d'une longueur de 122 cm, conçu pour une pression de 152 psi à 177 °C, calandre en acier au carbone certifiée pour une pression de 152 psi à 177 °C, référence 5-060-13-048-006, n° de série 95A10740-02, n° National Board 58817, année de fabrication 1996...

ITT - 5-060-13-048-006
Thermotran 23-120

239 Sq Ft Thermotran Heat Exchanger, S/S, 150/150#

Échangeur de chaleur Thermotran usagé de 239 sq ft, tubes en acier inoxydable avec (122) tubes de 0,75" de diamètre x 120" de long évalués à 150 psi à 450 °f, enveloppe en acier au carbone évaluée à 150 psi et vide complet à 450 °f, feuilles de tubes en acier au carbone, entrées/sorties d'enveloppe de 16", 6", 3" et 1", chapeau en acier au carbone avec (2)entrées/sorties de tubes de 3", manque (1)...

Thermotran - 23-120